PATIENT MONITOR CMS9000 & NiBP/SPO2/TEMP/ECG
VITAL SIGNS MONITOR CMS9000
Features:
– 12.1” Screen, Color TFT Screen, waveform up to 8 channels
– Light and portable with build-in rechargeable battery
– UP to 10 kinds of monitor parameters
– Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis
– 72 hour storage and review of trend grams and tables, 40 second review of olographic wavefo rms.
– Built-in recorder(option)
– All-round monitor of adult ,pediatric and neonatal.
– Electrosurgical unit and defibrillation protected
SPECIFICATIONS:
MODEL: CMS9000
Display: Colour TFT Screen
NIBP: Oscillometry
Method: Manual/Automatic/STAT
Operation Modes: mmGh/kPa selectable
Measurement unit: Systolic, Diastolic, Mean
Measurement Types: Adult 10 – 270mmHG
Measurement range: YES
Overpressure protection:1mmHg
Resolution: Mean error and standard deviation per ANSI/AAMI SP-10
Accuracy:
Alarm: Systolic, Diastolic, Mean
SP02: 0-100%
Measurement range: ±2 digit (70~100%) 0 ~69% unspecified
Accuracy:
Alarm range: 0-100%
ECG
Input:
Lead Selection:
Gain selection:
Accuracy:
Protection:
Calibration Signal:
Operation modes:
Alarm Range:
Peadiatric/Neonatal:
Alarm range:
S-T detection:
Alarm: 5-lead or 3-lead selectable
5-lead: RA, LA, RL, LL, V or R, L, N, F, C
I, II, III, avr, avl, avf, vx, CAL
12.5mm/s, 25mm/s, 50mm/s
±1bpm or ±1%, whichever is greater
Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
1mV±5%
Dianostic, Monitor, Surgery
15-300bpm
15-350bpm
-2.0mV~2.0mV
Yes, Arrhythmia analysis: YES
Yes, audible and visual alarm, alarm events recallable
RESPIRATION
Method:
Peadiatric/Neonatal:
Alarm range:
Peadiatric/Neonatal:
Apnea Alarm: RA-LL impedance
6-150rpm
6-120rpm
6-150rpm
YES
TEMPERATURE
Resolution:
Channel:
Alarm range: 0.1°C
Dual-channel
0-50°C
Option:
ETCO2
Measurement Mode
Measurement range:
Accuracy:
Apnea alarm: Side-stream or mainstream
EtC02: 0-99mmHg
CO2 concentration
YES
CO
Method:
Measurement range: Thermo-dilution
CO: 0.1-20Lit./min
IBP
Channel:
Pressure transducer:
Transducer sites:
Alarm range: 2 channels
Sensitivity: 5 (mV/V/mmHg)
ART, PA, CVP, RAP, LAP, ICP
-10~300mmHG
PLEASE SEND AN E-MAIL REGARDING STOCK AVAILABILITY, PRICE AND DELIVERY OPTIONS AND PRICES. PLEASE NOTE: Expected delivery dates or times given by us, our suppliers, or our couriers are given as a guide only. We cannot be held liable for any losses or costs incurred from delivery at a different date or time.